Inert Gas Fire Systems

Inert gas fire suppression systems

Inert gasoline suppression structures use argon and nitrogen gases and their mixtures as an extinguishing agent and are based in the principle of decreasing the oxygen awareness within the covered risk. The oxygen concentration is minimized by using the utility of inert gas until it reaches a level wherein combustion is not supported. Each machine is designed if you want to decrease oxygen to a specific level. When discharged, inert fuel is quickly and uniformly allotted inside the enclosure, achieving layout attention in 60 seconds.

Argon and nitrogen it is certainly present inside the atmosphere, consequently its inexperienced-residence effect is nil and its ozone layer depletion ability is 0. It is chemically inert, non-conductive, colourless, odourless and flavourless. Inert gasoline is non-corrosive and can be used at regular temperatures with such substances as nickel, metallic, stainless-steel, copper, brass, bronze and plastics.

These gases will never be re-classified as “hazardous waste” nor require special inspection procedures under the EU’s “F” Gas Regulations.

Inert gas fire suppression systems are the safe, natural way to extinguish a fire. Because of its unique patented valve assembly, inert gas agent enters the protected room within the industry required 60 seconds but at a steady flow rate — preventing destructive turbulence from occurring.

Inert gas fire systems, previously available in 150 and 200 bar cylinders, are now available with 300 bar gaseous fire protection technology. That means more inert gas in each cylinder, reducing the number of cylinders and accessory equipment necessary. In addition to a sizable reduction in system cost, fewer cylinders translates into an inert gas fire protection solution that takes less valuable space.

Multiple fire extinguishers lined up on grass, ready for emergency use, showcasing fire safety equipment.

marineretrofit gives all the blessings of Inert gas fire systems with several good sized layout improvements. You’ll locate the inert gasoline structures answer is safer and more low cost than some other machine in the marketplace.

Most inert gas systems discharge from the garage cylinders at excessive strain, after which use pressure reducers similarly down the pipe community (consequently requiring both high- and low-stress piping to handle the pressurized inert gasses as it travels to the release nozzles). marineretrofit inert gasoline structures is one-of-a-kind. Our superior cylinder strain regulator robotically reduces the pressure of the saved inert gasses at discharge.

We offer a great discharge strain and keep a consistent glide fee for the duration of the machine. That means no need for highly-priced high-pressure piping. With inert fuel systems, you can use small-diameter, low-pressure piping from the storage cylinders/manifold all of the manner to the nozzles, thus lowering your gadget costs.

Because of the particular pressure regulated valve meeting, the marineretrofit inert gasoline systems agent enters the included room in the required 60 seconds at a constant float price, preventing unfavourable turbulence from going on.

Therefore, most effective the amount of inert gasoline you actually need is discharged, and the essential venting place is lots smaller — you may reduce your installation charges through as a whole lot as 60% on venting hardware.

Inert Gas Suppression System Installation

Like any fire suppression system installation, an Inert fire suppression system should only be installed by a specialist fire suppression installation company such as ourselves. Any area to be protected by an Inert gas fire suppression system must be accurately measured to ensure the correct amount of agent is used to sufficiently suppress a fire/potential fire within the specific risk area. This is especially important for inert gas suppression systems such as IG55 systems, IG541 systems and Inergen systems due to the Oxygen reducing properties used to extinguish a fire. We provide complete fire suppression system installation including cylinders, detection, alarm, pipework and interfacing to ‘house-alarm’ system.

The marineretrofit Fire Suppression Systems are safe, clean and a natural way to extinguish fire. marineretrofit offers IG01, IG100, IG55 and IG541 Gasses with all the components needed to configure a complete system for 200/300 bar inert gas extinguishing agent. Full range of cylinders with 67, 80 and 140 litre capacities.

IG01 – 100% Argon

IG100 – 100% Nitrogen

IG55 – 50% Argon+ 50% Nitrogen

IG541- 52% Nitrogen+ 40% Argon+ 8% CO2

Cost-effective multi-zone systems with extinguishing gas storage can be implemented for several extinguishing zones. High degree of flexibility for modification or extension, thanks to the Gielle storage system. Gielle technology enables a more compact storage of the extinguishing agent, requiring up to 50% less space.

FIRE-FIGHTING PRODUCTS AND SOLUTIONS

Immediate price quote – the right solution for all your needs!

Marineretrofit offers top-notch maritime solutions, combining extensive talent and expertise. Whether you need portable fire equipment, fire protection systems, installation, repair, or ship overhaul, we’re here to provide comprehensive safety and support tailored to your needs. Trust Marineretrofit for all your maritime safety solutions.

× How can I help you?